Microcell
Retrofitable
weighing system:
Often copied - never
matched - the retrofitable weighing system based on semi-conductor
strain gauges.
The Microcell weighing system gives the possibility to retrofit
existing silos with a maintenance-free weight measurement system.
The installation can be completed within a few hours without
modification of the support construction.
The patented MicrocellJ are simply bolted to the support members
(legs) of the silo.
The
Microcell is sensing the deflection (tension, com-pression) in
the
material and converts this into a weight proportional voltage signal
which
is standardized and displayed by the electronic unit.
This method is specially suitable for big storage silos on legs (cement,
coal, chalk, blaster, ...) or skirted- and batching silos.
Advantages:
- Setting-up out of
container
- Installation without interruption of production process
- Permanent display of filling level and weight
- Free of maintenance
Construction of
the sensors:
The Microcell-sensor
consists of a pair of semi-conductor extension measuring strips, which are
ceramically connected to a bending bar made of nickel-plated building
steel, stainless steel or AIMg3.
Due to the half-bridge connection of the semi-conductor extension
measuring strips, the usually with semi-conductors appearing temperature
drift is compensated.
All Microcell-sensors are tested material-specific in a temperature
unit and re-compensated.
When sensors are installed at a bearing element, any distortion causes a
weight proportional change
of the resistance, which lines up at the output voltage and which is
processed by the following
electronical unit.

Silo
safety devices / level measurement
measuring/weighing |